Hi,
I encounter a weird bug when I want to do a blind scan with CrazyScan. Here is a screenshot of the issue:

8b072c84369.png


As soon as the following frequency (12235 V 4000, Türksat 3A/4A @ 42° East) is reached the search will not continue.

I've tried the latest StreamReaderEx-BDA 1.2.4.60 and older versions as well but still no luck. It drives me crazy. Blind scan will never complete even if I don't use BlindScan 2 option.

With the slower blind scan method it is much worse. It shuttles between two frequencies and never goes on.

I also tried EBSPro and got the same result. Once it hits this magical freq. it stops right there and the green LED light of TBS 5520 SE is flashing incessantly.

I don't think this is a tuner related issue because I can lock this freq. in DVB Dream without any problem.


Does anyone have any suggestions regarding this annoying problem?


Here is the StreamReader.log:

Code:
11:47:35 - 08/07/2018 StreamReaderEx BDA Ver:1.2.4.52-commited (Feb  3 2018, 19:08:52)
11:47:35 - 08/07/2018 Log level = 1
11:47:35 - 08/07/2018 DLL_PROCESS_ATTACH hModule = 5F430000
11:47:35 - 08/07/2018 CheckForDVBExEx(0x04E74F86)
11:47:35 - 08/07/2018 PID filtering disabled !
11:47:35 - 08/07/2018 Power-off LNB on exit: ENABLED
11:47:35 - 08/07/2018 SendDiSEqC use 2 repeats
11:47:35 - 08/07/2018 Default modulation: AUTO
11:47:35 - 08/07/2018 Default spectral inversion: AUTO
11:47:36 - 08/07/2018 Default pilot: AUTO
11:47:36 - 08/07/2018 Default rolloff: AUTO
11:47:36 - 08/07/2018 Preffered BDA device type: AUTO
11:47:36 - 08/07/2018 Allowed IF Freq 950-2150 Mhz
11:47:36 - 08/07/2018 Inverted LOF<6000 and >21000 Mhz
11:47:36 - 08/07/2018 Available BDA-devices:
11:47:36 - 08/07/2018 Device 0
11:47:36 - 08/07/2018 	Name: TBS 5520 BDA Tuner
11:47:36 - 08/07/2018 	Type: DVB-S/S2
11:47:36 - 08/07/2018 	Index: 0
11:47:36 - 08/07/2018 StartDVBEx(0)
11:47:36 - 08/07/2018 Device_ID: 0
11:47:36 - 08/07/2018 Use Device 0
11:47:36 - 08/07/2018 	Tuner filter: TBS 5520 BDA Tuner
11:47:36 - 08/07/2018 	Capture filter: TBS 5520 BDA Capture
11:47:36 - 08/07/2018 Input num 0
11:47:37 - 08/07/2018 Sat chip info - Airoha AV2018
11:47:37 - 08/07/2018 Ter chip info - Si2157-A30 ROM50 NVM3_0b5, running 'FW_3_0b5'
11:47:37 - 08/07/2018 Demod chip info - Si2183-B60 ROM2 NVM6_0b1, running 'FW_6_0b2'
11:47:37 - 08/07/2018 Turbosight Si2183 direct control used !
11:47:37 - 08/07/2018 RFScan delay = 5 ms
11:47:37 - 08/07/2018 Turbosight (QBOX - Cypress FX2 based) BDA extension used !
11:47:37 - 08/07/2018 + Turbosight BlindScan support with Unknown
11:47:37 - 08/07/2018 + Turbosight IR control support
11:47:37 - 08/07/2018 + Turbosight CI support
11:47:37 - 08/07/2018 + Turbosight I2C access support
11:47:37 - 08/07/2018 + Turbosight fast LNB control support
11:47:37 - 08/07/2018 + Turbosight SignalEx support
11:47:37 - 08/07/2018 + Turbosight MIS filtering support
11:47:37 - 08/07/2018 + Turbosight PLS control support
11:47:37 - 08/07/2018 SetChannelExEx(12750000, 30000000, 0, 0, 9750000, 10600000, 11700000, 1, 0, 0, 0)
11:47:39 - 08/07/2018 Not lock !
11:48:42 - 08/07/2018 SetChannelExEx(11621822, 2222000, 1, 5, 9750000, 10600000, 11700000, 1, 0, 0, 0)
11:48:43 - 08/07/2018 Signal RFLevel=-42 dBm
11:48:43 - 08/07/2018 Locked: SNR=11.750000 dB, BER=1.000000, Level=100%, Quality=0%
11:48:43 - 08/07/2018 Current Frequency: 11621.789 Mhz
11:48:43 - 08/07/2018 Current SymbolRate: 2222 KS/s
11:48:43 - 08/07/2018 Current Spectral Inversion: NORMAL
11:48:43 - 08/07/2018 Current Modulation: QPSK
11:48:43 - 08/07/2018 Current Inner FEC Method: Viterbi
11:48:43 - 08/07/2018 Current Inner FEC Rate: 5/6
11:48:43 - 08/07/2018 Current Outer FEC Method: Reed-Solomon 204/188
11:48:43 - 08/07/2018 Current Pilot: AUTO
11:48:43 - 08/07/2018 Current RollOff: 0.35
11:48:43 - 08/07/2018 DelFilter(0)
11:48:43 - 08/07/2018 Filter with ID 0 not exists !
11:48:43 - 08/07/2018 SetFilter(8192, 0x04E7545E, 4, 1, 0x02988BB8)
11:48:43 - 08/07/2018 filter_num=0
11:49:11 - 08/07/2018 SetChannelExEx(11649841, 13601000, 1, 2, 9750000, 10600000, 11700000, 1, 0, 0, 0)
11:49:11 - 08/07/2018 Signal RFLevel=-38 dBm
11:49:11 - 08/07/2018 Locked: SNR=10.500000 dB, BER=1.000000, Level=100%, Quality=0%
11:49:11 - 08/07/2018 Current Frequency: 11649.806 Mhz
11:49:11 - 08/07/2018 Current SymbolRate: 13601 KS/s
11:49:11 - 08/07/2018 Current Spectral Inversion: NORMAL
11:49:11 - 08/07/2018 Current Modulation: QPSK
11:49:11 - 08/07/2018 Current Inner FEC Method: Viterbi
11:49:11 - 08/07/2018 Current Inner FEC Rate: 2/3
11:49:11 - 08/07/2018 Current Outer FEC Method: Reed-Solomon 204/188
11:49:11 - 08/07/2018 Current Pilot: AUTO
11:49:11 - 08/07/2018 Current RollOff: 0.35
11:49:11 - 08/07/2018 DelFilter(0)
11:49:11 - 08/07/2018 SetFilter(8192, 0x04E7545E, 4, 1, 0x02988BB8)
11:49:11 - 08/07/2018 filter_num=1
11:50:15 - 08/07/2018 SetChannelExEx(11053825, 30001000, 1, 3, 9750000, 10600000, 11700000, 2, 0, 0, 0)
11:50:15 - 08/07/2018 Signal RFLevel=-32 dBm
11:50:15 - 08/07/2018 Locked: SNR=9.500000 dB, BER=1.000000, Level=100%, Quality=0%
11:50:15 - 08/07/2018 Current Frequency: 11053.770 Mhz
11:50:15 - 08/07/2018 Current SymbolRate: 30001 KS/s
11:50:15 - 08/07/2018 Current Spectral Inversion: NORMAL
11:50:15 - 08/07/2018 Current Modulation: 8PSK
11:50:15 - 08/07/2018 Current Inner FEC Method: Low Density Parity Check
11:50:15 - 08/07/2018 Current Inner FEC Rate: 3/4
11:50:15 - 08/07/2018 Current Outer FEC Method: Bose-Chaudhuri-Hocquenghem
11:50:15 - 08/07/2018 Current Pilot: ON
11:50:15 - 08/07/2018 Current RollOff: 0.20
11:50:15 - 08/07/2018 Current Frame Type: Long
11:50:15 - 08/07/2018 Current Coding Mode: CCM
11:50:15 - 08/07/2018 Current Stream Type: Transport
11:50:15 - 08/07/2018 Current Input Stream: Single
11:50:15 - 08/07/2018 DelFilter(1)
11:50:15 - 08/07/2018 SetFilter(8192, 0x04E7545E, 4, 1, 0x02988BB8)
11:50:15 - 08/07/2018 filter_num=2
11:55:09 - 08/07/2018 Scan decision timeout (blind_mode = 1)

11:56:43 - 08/07/2018 Scan decision timeout (blind_mode = 1)

11:58:33 - 08/07/2018 Scan decision timeout (blind_mode = 1)

12:05:04 - 08/07/2018 Scan decision timeout (blind_mode = 1)

12:12:19 - 08/07/2018 DelFilter(2)
12:12:19 - 08/07/2018 StopDVB()
12:12:19 - 08/07/2018 LNB power-off ok !
12:12:19 - 08/07/2018 DLL_PROCESS_DETACH hModule = 5F430000

Thanks.
 
Last edited:
Top