Firmware for Ferguson HF8900HD

rabedu

Registered
Messages
32
Neue Emusoft Ferguson HF8900HD_11.26.1D_Hivion

Neue Emusoft Ferguson HF8900HD_11.26.1D_Hivion
 
Last edited by a moderator:

rabedu

Registered
Messages
32
Neue Emusoft Ferguson HF8900HD_11.26.2D_Hivion

SSSP – Simple Serial Sharing Protocol
=====================================

This Protocol defines the communication between a DVB Box and a gbox by using a RS232(serial/com/tty port) with only 4 commands to implement.


RS232 communication settings
============================
115200 8N1 (115200 Baud, 8 data bits, no parity, 1 stop bit)
To activate add in the gbox_cfg R: { 01 } for com1, or R: { 02 } for com2
W: and V: should be deactivated 00 00
When developing Software you can activate thers232 debug messages by adding
10 to the R: parameter, a example for com1 would be R: { 11 }


Format of data
==============
AB CD EF GH ....

AB = Command
CDEF = length of the data following
GH ... = data

Total length is CDEF + 3 (1 byte command + 2 bytes len)


Command 0x means from STB to gbox
Command Fx means from gbox to STB


SEND PMT = 01 (send PMT to gbox)
--------------------------------
01 xx xx yy yy zz zz zz zz data ....
xx = Len
yy = SID ( byte 2 and bytes 3 from the PMT)
zz = PMT CRC32 (last 4 bytes in the PMT)
Data = CAID1 (2 bytes) PID1 (2 bytes) PROVIDER1 (3 bytes) CAID2 PID2 PROVIDER2 ....
Provider is only used in Seca and Viaccess, in other systems put 00 00 00
For Seca use 00 xx yy and for viaccess xx yy z0

On each channel change the DVB box must send the PMT first, on FTA Channels please send: 01 00 06 yy yy zz zz zz zz


SEND ECM = 03 (send ECM to gbox)
--------------------------------
03 xx xx yy yy ecm_data ....
xx = len
yy = pid

Note: Please send every ecm only once, do not send the same ecm multiple times.


REQUESTING PIDS DATA = F1 (receive ECM pid list )
-------------------------------------------------
F1 xx xx pid1 pid2 pid3 ....
xx = Len
pidx = 2 bytes for each pid

Please send me ECM data from these pids only, close all other already open.


CW RETURN = F2 (receive ControlWords)
-------------------------------------
F2 00 10 cw1 (8 bytes) cw2 (8 bytes)


Command flow on a channel change
================================
1. DVB box sends PMT with command 01 on a channel change
2. gbox sends pid list of the ecm's it can handle with command F1
3. DVB box sends ECM's (from all pids in the pid list) with command 03
4. gbox sends CW's with command F2
5. As soon the gbox has success in decoding a ecm it sends again a F1 command
with one pid only, the DVB box should close then all other pids and from
now on send only ecm data from that pid.

After this command 03 and F2 will be repeated until a channel change.

On the next channel change the DVB should close all open pids and repeat the
above procedure.



//-----------------------------------------------------------------------------------------
//-----------------------------------------------------------------------------------------
//-----------------------------------------------------------------------------------------
//-----------------------------------------------------------------------------------------
Advanced protocol

cmd 01 and 03 are not enough for multi-channel.

so added



Advanced SSSP support = 04 (send cmd to gbox)
--------------------------------
04 xx xx yy yy
xx = Len
yy = check value ( returned )



Reply Advanced SSSP support = F4
-------------------------------------------------
F4 xx xx yy yy
xx = Len
yy = 2 bytes, returned from CMD 04







SEND PMT = 05 (send PMT to gbox)
--------------------------------
05 xx xx aa yy yy zz zz zz zz data ....
xx = Len
aa = which channel, less than 10, example 00=viewing channel, 01=pip channel, 02= timeshift, 03=recording 1, 04=recording 2,.....
yy = SID ( byte 5 and bytes 6 from the PMT)
zz = PMT CRC32 (last 4 bytes in the PMT)
Data = CAID1 (2 bytes) PID1 (2 bytes) PROVIDER1 (3 bytes) CAID2 PID2 PROVIDER2 ....
Provider is only used in Seca and Viaccess, in other systems put 00 00 00
For Seca use 00 xx yy and for viaccess xx yy z0

On each channel change the DVB box must send the PMT first, on FTA Channels please send: 05 00 07 aa yy yy zz zz zz zz


REQUESTING PIDS DATA = F5 (receive ECM pid list )
-------------------------------------------------
F1 xx xx aa pid1 pid2 pid3 ....
xx = Len
aa = from cmd 05
pidx = 2 bytes for each pid

Please send me ECM data from these pids only, close all other already open.





SEND ECM = 06 (send ECM to gbox)
--------------------------------
03 xx xx aa bb bb bb bb yy yy ecm_data ....
xx = len
aa = which channel, less than 10, example 00=viewing channel, 01=pip channel, 02= timeshift, 03=recording 1, 04=recording 2,.....
bb = 4bytes, tag, returned from cmd F6
yy = pid

Note: Please send every ecm only once, do not send the same ecm multiple times.


CW RETURN = F6 (receive ControlWords)
-------------------------------------
F2 00 15 aa bb bb bb bb cw1 (8 bytes) cw2 (8 bytes)
aa = which channel from cmd 06
bb = tag 4bytes from cmd 06
 
Last edited by a moderator:

baha2

Super VIP
Messages
6,530
20/10/2010

New firm Ariva_TT_1.13.1A

Code:
because of restrictions lists favorite channels to 100 items
channels were available through the Cyfrowy Polsat digit + will switch can be found
Favourite group called C + & Polsat.
 
Top